UV Curable Resins

How to Determine UV Cure Dose and Line Speed for Industrial Coatings

Line speed is an output, not an input. Start from irradiance, wavelength and film thickness, then derive the speed your process can actually hold.

The cure equation

Cure dose (mJ/cm²) = irradiance (W/cm²) × exposure time. Exposure time is the dwell under the lamp, derived from line speed: time = lamp length ÷ line speed. The irradiance must be measured at the substrate surface with a calibrated radiometer — not the lamp's nameplate. Match the lamp spectrum to the photoinitiator package: LED systems run at 365, 385, 395 or 405 nm, and a spectral mismatch silently drops conversion.

Parameters that set the window

ParameterTypical rangeCommon test method
UV/LED cure dose100–2,000 mJ/cm² (depends on wavelength/thickness)Internal (cure end-point)
Irradiance at surface0.5–4 W/cm²Calibrated radiometer
Cure wavelength365 / 385 / 395 / 405 nmInternal
Viscosity50–50,000 mPa·sASTM D2196; ISO 2555
Shore D hardness50–85ASTM D2240; ISO 868
Pencil hardnessH–6HASTM D3363; ISO 15184
Adhesion to metal / glass / PET0–1 (ISO) / 4B–5B (ASTM)ISO 2409; ASTM D3359
Volumetric shrinkage2–10 %Internal
Yellowing index (ΔYI after aging)≤3–10ASTM E313

Our WJX-500 UV diluent and PET UV resin are supplied with TDS values for viscosity, solids and recommended cure energy.

UV LED vs. mercury: a formulation-dependent choice

FactorUV LEDMercury
SpectrumNarrow, tunable (365–405 nm)Broad, includes shorter UV
Heat loadLowerHigher
Lamp lifeLongShorter
Photoinitiator matchMust match LED wavelengthsBroader absorption tolerated

Common UV coating failures

FailureRoot causeCorrective
Surface tackyOxygen inhibition, under-dose, wrong initiatorRaise effective dose; match spectrum; inerting or surface cure strategy
Poor metal/glass adhesionContamination, low surface energy, resin mismatchClean pretreatment + compatible primer/formulation
Incomplete through-cureFilm too thick, pigment absorption, poor UV penetrationReduce thickness; adjust initiator; staged/complementary curing
Cracking / brittle filmCrosslink density too high; substrate movementMore flexible oligomer; reduce thickness; optimize cure
YellowingInitiator choice; over-exposure; heat degradationLow-yellowing system; optimize spectrum/dose/temperature
Process note. Separate "surface dry" from "through-cure." A tack-free surface can hide an uncured underlayer that fails adhesion or chemical resistance later. Verify cure depth and degree of conversion, not just touch.

Frequently asked questions

How do you calculate UV cure dose?

Dose (mJ/cm²) equals irradiance (W/cm² measured at the substrate surface with a calibrated radiometer) multiplied by exposure time, which is line speed converted to dwell time under the lamp. Match the lamp spectrum to the photoinitiator absorption.

Why is a tack-free surface not proof of full cure?

Oxygen inhibition and spectral mismatch can leave the underlying layer uncured while the surface feels dry. Measure cure depth and degree of conversion separately; a surface-only check hides incomplete through-cure.

UV LED or mercury lamp — which should I choose?

LED offers a narrow, tunable spectrum, lower heat load and long life, but needs photoinitiators matched to those wavelengths. Mercury emits a broader spectrum at higher heat and shorter lamp life. The choice is formulation- and substrate-dependent.

How does coating thickness affect cure?

Thicker or pigmented/high-absorption films need more dose or a complementary curing strategy because UV penetration is limited. Build the process window from film thickness, adhesion, hardness and degree of conversion rather than line speed alone.