Four SGS RoHS reports on file, each carrying the issuing laboratory's own report number. We publish the reports themselves — not a badge, not a summary written by us. Every number on this page can be traced to a page of a PDF below.
Download links point to the laboratory's report as issued. All four reports were issued in Chinese — the English tables on this page are our translations of the original documents. Images inside the files were recompressed so the pages load on a phone; no page was removed, reordered or edited.
| Sample | Water-based polyurethane modified emulsion — WJX-1011S |
|---|---|
| Appearance as received | Milky white liquid |
| Substances analysed | Cadmium (Cd), lead (Pb), mercury (Hg), hexavalent chromium Cr(VI), 10 polybrominated biphenyls (PBBs), 10 polybrominated diphenyl ethers (PBDEs) |
| Result | All 24 determinations: not detected (N.D.) |
| Detection limits applied | 2 mg/kg for Cd, Pb, Hg and Cr(VI); 5 mg/kg for each PBB and PBDE congener |
| Methods | BS EN 1122; US EPA 3050B / 3051 / 3052; US EPA 3060A with 7196A; US EPA 8081A / 8270D / 3540C / 3550C |
| Sample | Water-based polyurethane modified emulsion — WJX-1011S |
|---|---|
| Appearance as received | Milky white liquid |
| Substances analysed | Cadmium (Cd), lead (Pb), mercury (Hg), hexavalent chromium Cr(VI), 10 polybrominated biphenyls (PBBs), 10 polybrominated diphenyl ethers (PBDEs) |
| Result | All 24 determinations: not detected (N.D.) |
| Detection limits applied | 2 mg/kg for Cd, Pb, Hg and Cr(VI); 5 mg/kg for each PBB and PBDE congener |
| Methods | BS EN 1122:2001 Method B; US EPA 3050B / 3051 / 3052; US EPA 3060A with 7196A; US EPA 8081A / 8270D / 3540C / 3550C (GC-MS) |
A translated English edition of this report will be published here alongside the original.
| Sample | Water-based emulsion (coating) — white liquid. Applicant reference: WJX-918S series, WJX-1011S to WJX-1019S series |
|---|---|
| Substances analysed | Cd, Pb, Hg, Cr(VI), PBBs, PBDEs, and the four phthalates DBP, BBP, DEHP, DIBP |
| Result | All determinations: not detected (N.D.) |
| Limits applied | 100 mg/kg for Cd; 1,000 mg/kg for Pb, Hg, Cr(VI), total PBBs, total PBDEs and each phthalate |
| Conclusion in the report | Results met the limits of RoHS Directive 2011/65/EU Annex II as amended by (EU) 2015/863 |
| Methods | IEC 62321 series, analysed by ICP-OES, UV-Vis and GC-MS |
| Sample | Water-based overprint varnish — white liquid. Applicant reference: WJX-918S series, WJX-1011S to WJX-1019S series |
|---|---|
| Substances analysed | Cd, Pb, Hg, Cr(VI), PBBs, PBDEs, and the four phthalates DBP, BBP, DEHP, DIBP |
| Result | All determinations: not detected (N.D.) |
| Limits applied | 100 mg/kg for Cd; 1,000 mg/kg for Pb, Hg, Cr(VI), total PBBs, total PBDEs and each phthalate |
| Conclusion in the report | Results met the limits of RoHS Directive 2011/65/EU Annex II as amended by (EU) 2015/863 |
| Methods | IEC 62321 series, analysed by ICP-OES, UV-Vis and GC-MS |
Two pages of paper per claim is a lot to read on a phone, so here is the same information in one table — the columns match the PDFs.
| Report No. | Laboratory | Date | Sample | Scope | Result |
|---|---|---|---|---|---|
| SH8103145/CHEM | SGS | 2022-10-20 | WJX-1011S water-based PU modified emulsion | Cd, Pb, Hg, Cr(VI), 10 PBBs, 10 PBDEs | All N.D. |
| SH3204751/CHEM | SGS | 2019-08-27 | WJX-1011S water-based PU modified emulsion | Cd, Pb, Hg, Cr(VI), 10 PBBs, 10 PBDEs | All N.D. |
| SHAEC1900701536 | SGS | 2019-01-16 | Water-based emulsion (coating), WJX-918S / 1011S–1019S series | Cd, Pb, Hg, Cr(VI), PBBs, PBDEs, DBP, BBP, DEHP, DIBP | All N.D. |
| SHAEC1900603804 | SGS | 2019-01-16 | Water-based overprint varnish, WJX-918S / 1011S–1019S series | Cd, Pb, Hg, Cr(VI), PBBs, PBDEs, DBP, BBP, DEHP, DIBP | All N.D. |
A compliance page is only worth the verification behind it. Four things you can do without trusting us:
Every report number above appears on page 1 of its PDF, together with the issue date and the page count (2 of 2, 8 of 8).
The 2019 reports carry the SGS inspection seal and/or the authorised signatory's name; the 2022 report carries the SGS-CSTC laboratory authorisation block.
Ask SGS directly, quoting the report number, and ask whether the report is genuine and still on file. We will supply the uncompressed original if you need it.
These reports cover the samples tested, not your shipment. If you need evidence for a specific lot, tell us the grade and we will quote a fresh test.
Most compliance questions go wrong at exactly this point, so we would rather state the boundary than let you infer it.
| RoHS | Four SGS reports, all determinations not detected — as listed above. We do not hold a "RoHS certificate"; RoHS compliance is demonstrated by test reports like these. |
|---|---|
| CE marking | We do not claim CE certification for these products. Adhesives and coatings supplied as raw materials for industrial converting are generally outside the scope of the directives that carry CE marking; where a downstream product needs CE, that assessment belongs to the manufacturer placing it on the market. |
| REACH | We do not claim REACH registration. Registration obligations fall on the EU importer or the only representative, per substance and per volume. We provide SDS and composition data so your registration or notification can be prepared. |
| FDA | Our medical packaging grades are formulated to the relevant FDA indirect food additive regulations (21 CFR 175.105 and 175.300). That is a formulation statement, not an FDA approval, and FDA does not approve adhesives as such. |
| ISO 11607 | This is the standard your sterile-barrier packaging is validated against. We supply material data that feeds into that validation; we do not issue ISO 11607 certificates. |
| ISO 9001 | Not claimed on this page unless stated with a certificate number and issuing body. Ask us and we will tell you exactly what is and is not in place. |
| Food contact | A RoHS report is not a food-contact declaration. For EU 10/2011 or FDA food-contact statements, ask separately — they are a different document with a different scope. |
The 2019 and 2022 reports list our applicant address as Nankai District, Jinhui Building. That was our office address at the time of testing. Production and shipping now take place at the Xiqing District plant given on the contact page. The PDFs are the laboratory's files as issued — nothing on them has been covered, cropped or retouched, which is why the old address is still visible.
Tell us the product and the market you are selling into. We will say what documentation exists and what would have to be tested.